Lexus ES manuals

Lexus ES: Dtc Check / Clear

DTC CHECK / CLEAR

CHECK DTC

(a) Connect the Techstream to the DLC3.

(b) Turn the engine switch on (IG).

(c) Turn the parking support alert system on.

(d) Turn the Techstream on.

(e) Enter the following menus: Body Electrical / Advanced Parking Guidance/ICS/Intuitive P/A / Trouble Codes.

(f) Check for DTCs.

Body Electrical > Advanced Parking Guidance/ICS/Intuitive P/A > Trouble Codes

CLEAR DTC

(a) Connect the Techstream to the DLC3.

(b) Turn the engine switch on (IG).

(c) Turn the parking support alert system on.

(d) Turn the Techstream on.

(e) Enter the following menus: Body Electrical / Advanced Parking Guidance/ICS/Intuitive P/A / Trouble Codes.

(f) Clear the DTCs.

Body Electrical > Advanced Parking Guidance/ICS/Intuitive P/A > Clear DTCs

READ NEXT:

 How To Proceed With Troubleshooting

CAUTION / NOTICE / HINT HINT: Use the following procedure to troubleshoot the parking support alert system. *: Use the Techstream. PROCEDURE 1. VEHICLE BROUGHT TO WORKSHOP NEXT

 No. 1 Clearance Warning Buzzer Circuit

DESCRIPTION This circuit consists of the No. 1 clearance warning buzzer and clearance warning ECU assembly. An ECU-excited type buzzer is used. The ECU operates the buzzers using a sound pattern that

 No. 2 Clearance Warning Buzzer Circuit

DESCRIPTION This circuit consists of the No. 2 clearance warning buzzer and clearance warning ECU assembly. An ECU-excited type buzzer is used. The ECU operates the buzzers using a sound pattern that

SEE MORE:

 Crankshaft Position - Camshaft Position Correlation Bank 1 Sensor A (P001600)

DESCRIPTION Refer to DTC P001001. Click here DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note P001600 Crankshaft Position - Camshaft Position Correlation Bank 1 Sensor A Deviation in the crankshaft position sensor signal and camshaft position senso

 Inspection

INSPECTION PROCEDURE 1. INSPECT FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY) (a) Measure the resistance according to the value(s) in the table below. Standard Resistance: Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 22 to 28 Ω If the result is not as s