Lexus ES manuals

Lexus ES: On-vehicle Inspection

ON-VEHICLE INSPECTION

PROCEDURE

1. INSPECT ACCELERATOR PEDAL SENSOR ASSEMBLY

(a) Connect the Techstream to the DLC3.

(b) Turn the engine switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Powertrain / Engine / Data List / Accelerator Position Sensor No. 1 Voltage and Accelerator Position Sensor No. 2 Voltage.

Powertrain > Engine > Data List

Tester Display

Accelerator Position Sensor No.1 Voltage

Accelerator Position Sensor No.2 Voltage

(e) Read the values displayed on the Techstream.

Standard Voltage:

Techstream Display

Condition

Specified Condition

Accelerator Position Sensor No. 1 Voltage

Accelerator pedal fully released

0.5 to 1.1 V

Accelerator pedal fully depressed

2.6 to 4.5 V

Accelerator Position Sensor No. 2 Voltage

Accelerator pedal fully released

1.2 to 2.0 V

Accelerator pedal fully depressed

3.4 to 4.75 V

If the result is not as specified, check the accelerator pedal sensor assembly, wire harness and ECM.

READ NEXT:

 Removal

REMOVAL PROCEDURE 1. REMOVE NO. 1 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY Click here 2. REMOVE ACCELERATOR PEDAL(W/SENSOR) ROD ASSEMBLY NOTICE: Avoid physical shock to the accelerator pedal se

 Installation

INSTALLATION PROCEDURE 1. INSTALL ACCELERATOR PEDAL ASSEMBLY (a) Engage the claw to install the accelerator pedal assembly. (b) Install the 2 bolts. Torque: 7.5 N·m {76 kgf·cm, 66 in

 Active Control Engine Mount (for Front Side)

SEE MORE:

 Knock Sensor 1 Bank 1 or Single Sensor Circuit Short to Ground (P032511,P033011)

DESCRIPTION A flat-type knock control sensor (non-resonant type) has a structure that can detect vibrations between approximately 5 kHz and 15 kHz. The knock control sensor is fitted onto the engine block to detect engine knocking. The knock control sensor contains a piezoelectric element which gene

 Clearance Warning ECU Power Source Circuit

DESCRIPTION This circuit provides power to operate the clearance warning ECU assembly. WIRING DIAGRAM CAUTION / NOTICE / HINT NOTICE: Inspect the fuses for circuits related to this system before performing the following procedure. PROCEDURE 1. CHECK HARNESS AND CONNECTOR (CLEARANCE WARNING EC

© 2016-2025 Copyright www.lexguide.net