INSPECTION

PROCEDURE

1. INSPECT FUEL LID LOCK WITH MOTOR ASSEMBLY

(a) Check the operation of the fuel lid lock with motor assembly (motor operation).

(1) Apply auxiliary battery voltage to the fuel lid lock with motor assembly connector, and check the operation of the fuel lid lock with motor assembly.

*a

Component without harness connected

(Fuel Lid Lock with Motor Assembly)

*b

Shaft Stroke

*c

Lever

*d

Shaft

OK:

Auxiliary Battery Connection

Specified Condition

Auxiliary battery positive (+) → Terminal 1 (B)

Auxiliary battery negative (-) → Terminal 2 (E)

Shaft retracts

If the result is not as specified, replace the fuel lid lock with motor assembly.

(b) Check the operation of the fuel lid lock with motor assembly (fuel lid courtesy switch).

(1) Measure the resistance according the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

2 (E) - 3 (B)

Shaft not pushed (On)

Below 1 Ω

2 (E) - 3 (B)

Shaft pushed (Off)

10 kΩ or higher

If the result is not as specified, replace the fuel lid lock with motor assembly.

(c) Measure the shaft stroke.

Standard:

Area

Condition

Specified Condition

Shaft stroke

Lever pulled

16.05 mm (0.632 in.)

If the result is not as specified, replace the fuel lid lock with motor assembly.

READ NEXT:

 Installation

INSTALLATION PROCEDURE 1. INSTALL FUEL LID LOCK WITH MOTOR ASSEMBLY (a) Apply MP grease to the sliding parts of the fuel lid lock with motor assembly. (b) Connect the connector. (c) Engage the 2 claws

 Fuel Lid Opener Switch

 Components

COMPONENTS ILLUSTRATION *1 COWL SIDE TRIM BOARD LH *2 FRONT DOOR OPENING TRIM COVER LH *3 FRONT DOOR SCUFF PLATE LH *4 FUEL LID OPENER SWITCH (TRUNK AND FUEL SWITCH ASSEMBLY) *

SEE MORE:

 Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure (P1CFF62)

DTC SUMMARY MALFUNCTION DESCRIPTION If there is a large difference between the reactor current sensor value and the HV battery current sensor value, a malfunction will be detected. Internal inverter malfunction Current sensor malfunction Inverter with converter assembly internal circuit malfunc

 Warning Notification Function Malfunction

PROCEDURE 1. CHECK PROBLEM SYMPTOM (WARNING NOTIFICATION FUNCTION) (a) Check the problem symptom. (1) Check the problem symptom of the warning notification function. Result Proceed to The multi-display screen does not show a warning message even though a warning light turns on or t