Lexus ES manuals

Lexus ES: Initialization

INITIALIZATION

INITIALIZE PARKING ASSIST MONITOR SYSTEM

(a) When "!" mark is displayed on the image of the area behind the vehicle, perform the following procedure to correct the steering angle neutral point.

(1) Fully turn the steering wheel to the right and left on flat ground.

NOTICE:

Memorizing the steering angle neutral point must be carried out with the engine started. Apply the parking brake, depress the brake pedal, check that the shift lever is in P, and ensure that the vehicle is not moving.

HINT:

If "!" mark is displayed on the image of the area behind the vehicle with the steering wheel fully turned to the right or left, perform "Steering Angle Setting in Calibration".

Click here

READ NEXT:

 Parts Location

PARTS LOCATION ILLUSTRATION *1 ECM *2 REAR TELEVISION CAMERA ASSEMBLY *3 BLIND SPOT MONITOR SENSOR RH (w/ Blind Spot Monitor System) *4 BLIND SPOT MONITOR SENSOR LH (w/ Blind Spot

 Precaution

PRECAUTION PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE BATTERY TERMINAL NOTICE: When disconnecting the cable from the negative (-) battery terminal, initialize the following systems after the cab

 Problem Symptoms Table

PROBLEM SYMPTOMS TABLE NOTICE: The following inspection procedures for the parking assist monitor system are based on the assumption that the audio and visual system*1 or navigation system*2 is nor

SEE MORE:

 Control Module Internal Temperature Sensor/Intake Air Temperature Sensor Signal Compare Failure (P111C62)

DESCRIPTION The engine has an ECM internal temperature sensor and intake air temperature sensor. The resistance of a thermistor within the ECM internal temperature sensor and intake air temperature sensor increases as the temperature decreases and decreases as the temperature increases. The voltage

 Evaporative Emission System Switching Valve Control Circuit Actuator Stuck Off (P24187F)

DTC SUMMARY DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note P24187F Evaporative Emission System Switching Valve Control Circuit Actuator Stuck Off Following condition is met during key-off EVAP monitor: EVAP pressure change when vent valve closed

© 2016-2026 Copyright www.lexguide.net