DESCRIPTION
This DTC is stored when the blind spot monitor sensor RH detects an internal malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| C1AB6 | Blind Spot Monitor Master Module | The blind spot monitor sensor RH (master) detects an internal malfunction | Blind spot monitor sensor RH |
CAUTION / NOTICE / HINT
NOTICE:
When checking for DTCs, make sure that the blind spot monitor system is turned on.
PROCEDURE
| 1. | CHECK DTC |
(a) Turn the power switch off.
(b) Turn the power switch on (IG).
(c) Recheck for DTCs and check if the same DTC is output again.
Body Electrical > Blind Spot Monitor Master > Trouble CodesOK:
No DTCs are output.
| OK | | USE SIMULATION METHOD TO CHECK |
| NG | | REPLACE BLIND SPOT MONITOR SENSOR RH |
Blind Spot Monitor Slave Module (C1AB7)
Destination Information Undefined (C1AB8)
Blind Spot Monitor Master Module Beam Axis Inspection Incomplete (C1ABB)
Installation
Intermediate Shaft Speed Sensor "A" Circuit Short to Battery (P079112,P079114,P079131)