Lexus ES manuals

Lexus ES: Blind Spot Monitor Master Module (C1AB6)

DESCRIPTION

This DTC is stored when the blind spot monitor sensor RH detects an internal malfunction.

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

C1AB6

Blind Spot Monitor Master Module

The blind spot monitor sensor RH (master) detects an internal malfunction

Blind spot monitor sensor RH

CAUTION / NOTICE / HINT

NOTICE:

When checking for DTCs, make sure that the blind spot monitor system is turned on.

PROCEDURE

1.

CHECK DTC

(a) Turn the power switch off.

(b) Turn the power switch on (IG).

(c) Recheck for DTCs and check if the same DTC is output again.

Body Electrical > Blind Spot Monitor Master > Trouble Codes

OK:

No DTCs are output.

OK

USE SIMULATION METHOD TO CHECK

NG

REPLACE BLIND SPOT MONITOR SENSOR RH

READ NEXT:

 Blind Spot Monitor Slave Module (C1AB7)

DESCRIPTION This DTC is stored when the blind spot monitor sensor LH detects an internal malfunction. DTC No. Detection Item DTC Detection Condition Trouble Area C1AB7 Blind Spot Monito

 Destination Information Undefined (C1AB8)

DESCRIPTION This DTC is stored when correct destination information is not sent from the main body ECU (multiplex network body ECU) and destination information cannot be confirmed after a blind spot m

 Blind Spot Monitor Master Module Beam Axis Inspection Incomplete (C1ABB)

DESCRIPTION This DTC is stored when a beam axis inspection has not been performed for the blind spot monitor sensor RH. HINT: This DTC is always stored after replacing a blind spot monitor sensor. The

SEE MORE:

 Check Bus 2 Lines for Short Circuit

DESCRIPTION There may be a short circuit between the CAN main bus lines and/or CAN branch lines when the resistance between terminals 18 (CA4H) and 17 (CA4L) of the central gateway ECU (network gateway ECU) is below 54 Ω. Symptom Trouble Area Resistance between terminals 18 (CA4H) and 17 (

 Automatic High Beam Switch Indicator does not Come ON

DESCRIPTION When the automatic high beam system is on, the steering sensor illuminates the automatic high beam switch indicator. WIRING DIAGRAM PROCEDURE 1. READ VALUE USING TECHSTREAM (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d

© 2016-2026 Copyright www.lexguide.net