Lexus ES manuals

Lexus ES: Dtc Check / Clear

DTC CHECK / CLEAR

CHECK FOR DTCS

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

Powertrain > Hybrid Control > Trouble Codes

(e) Check the DTCs and freeze frame data, and then write them down.

(f) Check the details of the DTCs.

Techstream Display

Description

Test Failed

Shows the malfunction judgment results during the current trip.

Confirmed

Shows the DTCs confirmed up to now. (The number of current trips differs for each DTC.)

HINT:

Freeze frame data is stored for both Test Failed DTCs and Confirmed DTCs.

CHECK FREEZE FRAME DATA

(a) If a DTC is stored, select it in order to display its freeze frame data.

(b) Read the freeze frame data recorded when the DTC was stored.

CLEAR DTCS

NOTICE:

Clearing the DTCs will also clear the freeze frame data.

for NICKEL METAL HYDRIDE BATTERY:

Click here

for LITHIUM-ION BATTERY:

Click here

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Turn the Techstream on.

(d) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

(e) Clear the DTCs and freeze frame data.

Powertrain > Hybrid Control > Clear DTCs

READ NEXT:

 Diagnosis System

DIAGNOSIS SYSTEM DLC3 (Data Link Connector 3) (a) Check the DLC3. Click here AUXILIARY BATTERY VOLTAGE Standard Voltage: Switch Condition Specified Condition Power switch on (IG) 11 to 1

 Dtc Check / Clear

DTC CHECK / CLEAR CHECK FOR DTCS (a) Connect the Techstream to the DLC3. (b) Turn the power switch on (IG). (c) Turn the Techstream on. (d) Enter the following menus: Powertrain / Hybrid Control / Tro

 Terminals Of Ecu

TERMINALS OF ECU *a Hybrid Vehicle Control ECU - - HINT: The standard normal voltage between each pair of hybrid vehicle control ECU terminals is shown in the table below. The appropriate

SEE MORE:

 Installation

INSTALLATION PROCEDURE 1. INSTALL LEAK DETECTION PUMP SUB-ASSEMBLY HINT: Only perform this procedure when replacement of the leak detection pump sub-assembly is necessary. (a) Engage the 2 claws to install a new leak detection pump sub-assembly to the charcoal canister sub-assembly. NOTICE:

 Inspection

INSPECTION PROCEDURE 1. INSPECT CAMSHAFT TIMING GEAR BOLT (a) Check the stroke of the plunger in the center of the camshaft timing gear bolt. Standard Stroke: 2.2 mm (0.0866 in.) or more HINT: When pressing the plunger, there may be a stepped feeling. This is not a malfunction. If the result is