DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate an abnormal resolver output signal. The cause of this malfunction may be one of the following:
HINT:
If any of these DTCs is output, a malfunction of the MG ECU circuit board or poor installation of a low voltage connector is suspected. It is not necessary to inspect the motor resolver.
DESCRIPTION
Refer to the system description for the Generator Resolver Circuit.
Click here
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
---|---|---|---|---|---|
P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | The value of the generator resolver sin phase signal is lower than the low side threshold. (1 trip detection logic) |
| Comes on | Master Warning Light: Comes on |
P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | The value of the generator resolver sin phase signal is higher than the high side threshold. (1 trip detection logic) |
| Comes on | Master Warning Light: Comes on |
P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | The value of the generator resolver cos phase signal is lower than the low side threshold. (1 trip detection logic) |
| Comes on | Master Warning Light: Comes on |
P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | The value of the generator resolver cos phase signal is higher than the high side threshold. (1 trip detection logic) |
| Comes on | Master Warning Light: Comes on |
MONITOR DESCRIPTION
The motor generator control ECU monitors the Generator resolver output signal. If the motor generator control ECU detects output signals that are out of the normal range or specification, it will conclude that there is a malfunction in the Generator resolver. If a malfunction is detected, the motor generator control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
Related DTCs | P0C66 (INF P0C6416): Out of range P0C67 (INF P0C6417): Out of range P0C6B (INF P0C6916): Out of range P0C6C (INF P0C6917): Out of range |
Required sensors/components | Generator resolver |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | 1 driving cycle |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored | TMC's intellectual property |
Other conditions belong to TMC's intellectual property | - |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0C66 (INF P0C6416) is not detected DTC P0C67 (INF P0C6417) is not detected DTC P0C6B (INF P0C6916) is not detected DTC P0C6C (INF P0C6917) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
Click here
Click here
HINT:
[*1] to [*5]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
HINT:
CAUTION / NOTICE / HINT
CAUTION:
Click here
HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a | Without waiting for 10 minutes |
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
HINT:
PROCEDURE
1. | CHECK DTC OUTPUT |
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble Codes Result | Proceed to |
---|---|
P0C6416, P0C6417, P0C6916 or P0C6917 only is output, or DTCs except the ones in the table below are also output. | A |
DTCs of hybrid control system in the tables below are output. | B |
DTCs of motor generator control system in the tables below are output. | C |
Malfunction Content | System | Relevant DTC | |
---|---|---|---|
Insulation Malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
Malfunction Content | System | Relevant DTC | |
---|---|---|---|
Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module Watchdog / Safety μC Failure |
P0A1A49 | Generator Control Module Internal Electronic Failure | ||
P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | |
Power source circuit malfunction | Motor generator control system | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
Communication malfunction | Motor generator control system | P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message |
HINT:
(e) Turn the power switch off.
B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
C | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
2. | CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
Result | Proceed to |
---|---|
OK | A |
NG (The connector is not connected securely.) | B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A | REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS |
B | CONNECT SECURELY |
C | REPAIR OR REPLACE HARNESS OR CONNECTOR |