DESCRIPTION

DTC No.

Detection Item

DTC Detection Condition

Trouble Area

MIL

Warning Indicate

P0E5111

DC/DC Converter Current Sensor Circuit Short to Ground

Short to GND detected in reactor current sensor circuit

(1 trip detection logic)

Inverter with converter assembly

Comes on

Master Warning Light:

Comes on

P0E5115

DC/DC Converter Current Sensor Circuit Short to Battery or Open

Open or short to +B detected in reactor current sensor circuit

(1 trip detection logic)

Inverter with converter assembly

Comes on

Master Warning Light:

Comes on

P0E511F

DC/DC Converter Current Sensor Circuit Intermittent

Short to GND, open or short to ground detected in reactor current sensor circuit when DTC P0C7917, P0D3319, P0E5717, P1C5D19 or P1C5F19 is stored.

(1 trip detection logic)

Inverter with converter assembly

Does not come on

Master Warning Light:

Does not come on

Related Data List

DTC No.

Data List

P0E5111

P0E5115

P0E511F

Inverter Input Current

MONITOR DESCRIPTION

If the motor generator control ECU detects an open or short in the DC/DC converter current sensor circuit, it will illuminate the MIL and store a DTC.

MONITOR STRATEGY

Related DTCs

P0E53 (INF P0E5111): DC/DC Converter Current Sensor Range check (Low voltage)

P0E54 (INF P0E5115): DC/DC Converter Current Sensor Range check (High voltage)

Required sensors/components

DC/DC converter current sensor

Frequency of operation

Continuous

Duration

TMC's intellectual property

MIL operation

Immediately

Sequence of operation

None

TYPICAL ENABLING CONDITIONS

The monitor will run whenever the following DTCs are not stored

TMC's intellectual property

Other conditions belong to TMC's intellectual property

-

TYPICAL MALFUNCTION THRESHOLDS

TMC's intellectual property

-

COMPONENT OPERATING RANGE

Motor generator control ECU

DTC P0E53 (INF P0E5111) is not detected

DTC P0E54 (INF P0E5115) is not detected

CONFIRMATION DRIVING PATTERN

HINT:

  • After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

    Click here

  • When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.

    Click here

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 2 minutes or more.
  5. Turn the power switch on (IG) and turn the Techstream on.
  6. With power switch on (IG) and wait for 5 seconds or more. [*1]

    HINT:

    [*1]: Normal judgment procedure.

    The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.

  7. Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
  8. Check the DTC judgment result.

    HINT:

    • If the judgment result shows NORMAL, the system is normal.
    • If the judgment result shows ABNORMAL, the system has a malfunction.
    • If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.

CAUTION / NOTICE / HINT

CAUTION:

  • Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
    • Inspecting the high-voltage system
    • Disconnecting the low voltage connector of the inverter with converter assembly
    • Disconnecting the low voltage connector of the HV battery
  • To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
  • After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here

    HINT:

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

    *a

    Without waiting for 10 minutes

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here

PROCEDURE

1.

REPLACE INVERTER WITH CONVERTER ASSEMBLY

Click here

NEXT

COMPLETED

READ NEXT:

 DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure (P0E5128)

DTC SUMMARY MALFUNCTION DESCRIPTION This DTC is stored when an abnormal current sensor output signal is detected. The cause of this malfunction may be one of the following: Internal inverter malfunct

 DC/DC Converter Current Sensor Signal Stuck In Range (P0E512A)

DTC SUMMARY MALFUNCTION DESCRIPTION This DTC is stored if the value of the reactor current sensor does not change. The cause of this malfunction may be one of the following: Area Main Malfunction

 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold (P0E5717)

DTC SUMMARY MALFUNCTION DESCRIPTION If an overvoltage malfunction occurs in the motor inverter or generator inverter, the motor generator control ECU (MG ECU) detects the malfunction and stores this D

SEE MORE:

 Low Pressure Fuel System Pressure - Too High (P008B00)

DESCRIPTION Refer to DTC P008A00. Click here DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note P008B00 Low Pressure Fuel System Pressure - Too High The actual fuel pressure (for low pressure side) value is higher than target fuel pressure (for low p

 Diagnostic Trouble Code Chart

DIAGNOSTIC TROUBLE CODE CHART Motor Generator Control System DTC No. Detection Item MIL Warning Indicate Link P033500 Crankshaft Position Sensor "A" Does not come on Master Warning Light: Comes on P033531 Crankshaft Position Sensor "A" No Signal Does not come on M